Technical rules for system fans
Your server supports two types of fans:  
•  Standard fan (27000 RPM)
•  Performance fan (29000 RPM)
Server model
Fan type
With GPUs/CX6 adapters Without GPUs/CX6 adapter
8 x 2.5'', 8 x 3.5'', 
16 x 2.5''
Performance
Standard
12 x 3.5'', 24 x 
2.5''
Performance
Performance
backplane-less
Performance
Performance
Notes: 
•  If your server is configured with one processor, five system fans (fan 1 to fan 5) are adequate to provide 
proper cooling. However, you must keep the location for fan 6 occupied by a fan filler to ensure proper 
airflow. Install fan 6 when there are two processors onboard.
•  If there is an OCP 3.0 Ethernet adapter installed, when the system is powered off but still plugged in to AC 
power, fan 1 and fan 2 will continue to spin at a much lower speed. This is the system design to provide 
proper cooling for the OCP 3.0 Ethernet adapter.
148
ThinkSystem SR665 Maintenance Manual