Step 5. Install the 7mm drive cage to the riser cage.
Figure 159. 7mm drive cage installation
a. Align the left-side pin on the 7mm drive cage with the positioning slot on the securing clip, the
two holes on the side brackets of the 7mm drive cage with the two holes on the front of the
riser cage.
b. Install the two screws to secure the 7mm drive cage in place
Step 6. Install the riser 2 assembly to the riser 2 slot on the system board. See “Install a PCIe adapter and
riser 1/2 assembly” on page 350.
After you finish
1. Reinstall all the drives and fillers (if any) into the drive bays. See “Install a hot-swap drive” on page 178.
2. Complete the parts replacement. See “Complete the parts replacement” on page 397.
344
ThinkSystem SR665 Maintenance Manual