5 Motor control (MCTRL)
5.4 V/f characteristic control (VFCplus)
Lenze · 8400 BaseLine C · Reference manual · DMS 1.6 EN · 01/2014 · TD05 79
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter Info Parameter Info Parameter Info
1 C022 Imax in motor mode 9 C021 Slip compensation 13 C006 Motor control
2 C023 Imax in generator mode 10 C058 Output frequency 14 C015 V/f base frequency
3 C074 Ti Imax controller 11 C910/1 Max. pos. output frequency 15 C016 Vmin boost
4 C073 Vp Imax controller 12 C910/2 Max. neg. output frequency 16 C018 Switching frequency
5 C050 Speed setpoint
6 C909/1 Max. pos. speed
7 C909/2 Max. neg. speed
8 C105 Deceleration time - quick stop