Function block library
7-239
SHB9300CRV EN 2.0
Output of status information
l
WELD-T-ERR = HIGH:
Total length and time of three sections do not match
WELD-LEN-C (close),
WELD-TIME (weld)and
WELD-LEN-O (open).
Reasons can be:
Wrong profile selection
Line speed too high
In such a case the welding time will be automatically reduced to avoid a disturbance or interruption
of the motion sequence.
Y-Pos
X-Pos
WELD-LEN-C WELD-LEN-O
WELD-TIME
WELD-LEN
l
WELD-DIR-ERR = HIGH:
A negative master phase is assigned to the input WELD-XIN.
Remedy:
Invert master phase
Invert the direction of rotation of the welding bar drive before FB CCTRL.
l
WELD-ON = HIGH:
Welding phase active
Show/Hide Bookmarks