Configuration
7-312
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C0182 Ti S-curve 20.00 0.01 s {0.01 s} 50.00 s T
i
time of the S-curve ramp function generator for
NSET
Determines the S-curve
l
small values
A
minimum S rounding
l
high values
A
large S rounding
C0190 NSET arith 0 0{1}5Arithmetic block in the function block NSET.
Connects main setpoint C0046 and additional setpoint
C0040
0OUT=C46
1 C46 + C49
2 C46 - C49
3 C46 * C49
4 C46 / C49
5 C46/(100 - C49)
C0220 NSET Tir add 0.000 0.000 {0.001 s} 999.900 Acceleration time T
ir
of the additional setpoint for NSET
(ref. to speed change 0
¡
n
max.
)
C0221 NSET Tif add 0.000 0.000 {0.001 s} 999.900 Deceleration time T
if
of the additional setpoint for NSET
(ref. to speed change 0
¡
n
max.
)
C0241 NSET RFG I = O 1.00 0.00 {0.01 %} 100.00 Threshold ramp function generator for main setpoint
Input = output , (100 % = n
max
)
[C0780] CFG: N 50 AIN1-OUT
@
Selection list 1 Configuration main setpoint input
[C0781] CFG: N-INV 10251 R/L/Q-R/L
@
Selection list 2 Configuration main setpoint inversion
[C0782] CFG: NADD 5650 ASW1-OUT
@
Selection list 1 Configuration additional setpoint input
[C0783] CFG: NADD-INV 1000 FIXED0
@
Selection list 2 Configuration additional setpoint inversion
[C0784] CFG: CINH-VAL 5001 MCTRL-NACT
@
Selection list 1 Configuration output signal with controller inhibit
[C0785] CFG: SET 5000 MCTRL-NSET2
@
Selection list 1 Configuration ramp function generator
[C0786] CFG: LOAD 5001 MCTRL-QSP-OUT
@
Selection list 2 Digital input (load ramp function generator)
[C0787]
1
2
3
4
CFG: JOG*1
CFG: JOG*2
CFG: JOG*4
CFG: JOG*8
53
1000
1000
1000
@
Selection list 2
DIGIN3
FIXED0
FIXED0
FIXED0
Configuration JOG selection and JOG activation
Binary interpretation
[C0788]
1
2
3
4
CFG: TI*1
CFG: TI*2
CFG: TI*4
CFG: TI*8
1000
1000
1000
1000
@
Selection list 2
FIXED0
FIXED0
FIXED0
FIXED0
Configuration Ti selection and Ti activation
l
Binary interpretation
l
Tir and Tif pairs are identical
[C0789] CFG: RFG-0 1000 FIXED0
@
Selection list 2 Digital input (ramp function generator 0)
[C0790] CFG: RFG-STOP 1000 FIXED0
@
Selection list 2 Digital input (ramp function generator stop)
C0798
1
2
DIS: CINH-VAL
DIS: SET
-199.99 {0.01 %} 199.99 analog input signals
C0799
1
2
3
4
5
6
7
8
9
10
11
12
13
DIS: N-INV
DIS: NADD-INV
DIS: LOAD
DIS: JOG*1
DIS: JOG*2
DIS: JOG*4
DIS: JOG*8
DIS: TI*1
DIS: TI*2
DIS: TI*4
DIS: TI*8
DIS RFG-0
DIS: RFG-STOP
Display digital input signals of NSET
OR
[C0830]
1
2
3
CFG: IN1
CFG: IN2
CFG: IN3
1000 FIXED0
@
Selection list 2 Digital inputs OR1
C0831 DIS: C0830 Display of C0830