Configuration
7-311
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C1398
1
2
3
4
CFG: DFIN1
CFG: DFIN2
CFG: DFIN3
CFG: DFIN4
1000 FIXEDPHI-0
@
Selection list 4
1: Master value input 1
2: Master value input 2
3: Master value input 3
4: Master value input 4
C1399 DIS: C1398/1 ... 4 Display of C1398
NOT
[C0840] CFG: IN 1000 FIXED0
@
Selection list 2 Digital input NOT1
C0841 DIS: C0840 Display of C0840
[C0842] CFG: IN 1000 FIXED0
@
Selection list 2 Digital input NOT2
C0843 DIS: C0842 Display of C0842
[C0844] CFG: IN 1000 FIXED0
@
Selection list 2 Digital input NOT3
C0845 DIS: C0844 Display of C0844
[C0846] CFG: IN 1000 FIXED0
@
Selection list 2 Digital input NOT4
C0847 DIS: C0846 Display of C0846
[C0848] CFG: IN 1000 FIXED0
@
Selection list 2 Digital input NOT5
C0849 DIS: C0848 Display of C0848
NSET
C0011 Nmax 3000 500 {1 rpm} 16000 Maximum speed
Reference value for the absolute and relative setpoint
selection for the acceleration and deceleration times.
l
Parameter setting via interface:
Large changes in one step should only be made
when the controller is inhibited.
C0012 Tir (acc) 0,000 0,000 {0,001 s} 999.900 Acceleration time T
ir
for the main setpoint of NSET
(ref. to speed change 0
¡
n
max.
)
C0013 Tif (dec) 0.000 0.000 {0.001 s} 999.900 Deceleration time T
if
for the main setpoint of NSET
(ref. to speed change 0
¡
n
max.
)
C0039
1
2
3
4
5
...
14
15
JOG set-value
JOG set-value
JOG set-value
JOG set-value
JOG set-value
...
JOG set-value
JOG set-value
100.00
75.00
50.00
25.00
0.00
...
0.00
0.00
-199.99 {0.01 } 199.99 Fixed speeds (JOG setpoints)can be selec-
ted for NSET using digital inputs
C0045 DIS: act JOG 0Nsetactive
1JOG1
2JOG2
...
15 JOG 15
Active JOG set-value
C0046 DIS: N -199.99 {0.01 %} 199.99 Main setpoint
C0049 DIS: NADD -199.99 {0.01 %} 199.99 Additional setpoint
C0101
1
2
...
15
add Tir
add Tir
...
add Tir
0.
0.000
...
0.000
0,000 {0,001 s} 999.900 Additional acceleration times T
ir
for the
main setpoint of NSET
(ref. to speed change 0
¡
n
max.
)
C0103
1
2
...
15
add Tif
add Tif
...
add Tif
0.
0.000
...
0.000
0,000 {0,001 s} 999.900 Additional deceleration times T
if
for the
main setpoint of NSET
(ref. to speed change 0
¡
n
max.
)
C0130 DIS: act Ti Active T
i
times of NSET
C0134 RFG charac 0 0/1 Ramp characteristic for main setpoint
0: linear
1: S-curve
Show/Hide Bookmarks