Configuration
7-310
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C0988
1
2
3
4
5
6
7
DIS: C0970
DIS: C0973
DIS: C0974
DIS: C0975
DIS: C0976
DIS: C0977
DIS: C0978
-199.99 {0.01 %} 199.99 Display of
C0970
C0973
C0974
C0975
C0976
C0977
C0978
C0989
1
2
DIS: C0971
DIS: C0972
Display of
C0971
C0972
MPOT
C0260 MPOT1 high 100.00 -199.99 {0.01 %} 199.99 Motor potentiometer upper limit, condition: C0260 >
C0261
C0261 MPOT1 low -100.0 -199.99 {0.01 %} 199.99 Motor potentiometer lower limit, condition: C0261 <
C0260
C0262 MPOT1 Tir 10.0 0.1 {0.1 s} 6000.0 Motor potentiometer acceleration time T
ir,
Related to change 0
¡
100 %
C0263 MPOT1 Tif 10.0 0.1 {0.1 s} 6000.0 Motor potentiometer deceleration time T
if
Related to change 0
¡
100 %
C0264 MPOT1 on/off 0
0{1}5
Deactivation function of motor pot
l
Function which is executed when motor pot is deac-
tivated via the input MPOT1-INACTIVE.
0 no change
1
D
e
c
e
l
e
r
a
t
i
o
n
w
i
t
h
T
i
f
t
o
0
%
1
D
e
c
e
l
e
r
a
t
i
o
n
w
i
t
h
T
if
t
o
0
%
2 Deceleration with T
if
to C0261
3 JumpwithT
if
=0to0%
4 JumpwithT
if
= 0 to C0261
5 Acceleration with T
ir
to C0260
C0265 MPOT1 init 0
0{1}2
Initialization function of motor pot
l
Value which is accepted during mains switching and
activated motor pot.
0
V
a
l
u
e
d
u
r
i
n
g
m
a
i
n
s
f
a
i
l
u
r
e
a
c
t
i
v
a
t
e
d
m
o
t
o
r
p
o
t
.
0 Value during mains failure
1 lower limit of C0261
20%
[C0267]
1
2
CFG: UP
CFG: DOWN
1000 FIXED0
@
Selection list 2 Digital inputs motor potentiometers
[C0268] CFG: INACT 1000 FIXED0
@
Selection list 2 Configuration motor potentiometer input
C0269
1
2
3
DIS: C0267/1
DIS: C0267/2
DIS: C0268
Display of
DIS: C0267/1
DIS: C0267/2
DIS: C0268
MSEL
C1394
1
2
3
4
5
6
7
8
9
10
CFG: EN-M1
CFG: EN-M2
CFG: EN-M3
CFG: EN-M4
CFG: LOCK
CFG: EN-M1
CFG: EN-M2
CFG: EN-M3
CFG: EN-M4
CFG: LOCK
1000 FIXED 0
@
Selection list 2
1. MSEL1: Activation master value 1
2. MSEL1: Activation master value 2
3. MSEL1: Activation master value 3
4. MSEL1: Activation master value 4
5. MSEL1: Locking
6. MSEL2: Activation master position 1
7. MSEL2: Activation master position 2
8. MSEL2: Activation master position 3
9. MSEL2: Activation master position 4
10.MSEL2: Locking
C1395 DIS: C1394/1 ... 10 Display of C1394
C1396
1
2
3
4
CFG: M1POS
CFG: M2POS
CFG: M3POS
CFG: M4POS
1000 FIXED0 INC
@
Selection list 3
1. MSEL2: Master position input 1
2. MSEL2: Master position input 2
3. MSEL2: Master position input 3
4. MSEL2: Master position input 4
C1397 DIS: C1396/1 ... 4 Display of C1396