Configuration
7-316
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C0993 DIS: C0991 Display of C0991
[C1030] CFG: IN 1000 FIXEDPHI0
@
Selection list 4 Input PHINT2
[C1031] CFG: RESET 1000 FIXED0
@
Selection list 2 Reset input of PHINT2
C1032 DIS: C1030 -32767 {1} 32767 Display of C1030
C1033 DIS: C1031 Display of C1031
C1150 Function 0 0 Load perm
1 Load edge
2Cmp&sub
Function of PHINT3
C1151 Comp. value 2
ô
10
9
0 {1} 2000000000 Comparison value of PHINT3
[C1153] CFG: IN 1000 FIXEDPHI0
@
Selection list 4 Input phase integrator PHINT3
[C1154] CFG: LOAD 1000 FIXED0
@
Selection list 2 Input of PHINT3
[C1155] CFG: SET 1000 FIXED0INC
@
Selection list 3 Input of PHINT3
C1157 DIS: C1153 -32767 {1} 32767 Display of C1153
C1158 DIS: C1154 Display of C1154
C1159 DIS: C1155 -2147483647 {1} 2147483647 Display of C1155
PSAVE
C1430
1
2
Window for master
value comparison
Window for actual
value comparison
1.0000 0 {0.0001 units} 214000.0000
C1431 Memory function 0 0{1]20 Compare MPOS and ACTPOS
1 compare MPOS only
2 compare ACTPOS only
C1434
1
2
CFG: ON
CFG: SAVE
1000 FIEXED0
@
Selection list 2 1. HIGH = Comparison of inputs MPOS/ACTPOS with
values saved and difference output
2. HIGH = Acceptance of the inputs MPOS and ACTPOS
C1435 DIS: C1434/1 ... 2 Disply of C1434
C1436
1
2
CFG: MPOS
CFG: ACTPOS
1000 FIXED0INC
@
Selection list 3 1. Input for master position
2. Input for actual position (e.g. rotor position)
C1437 DIS: C1436/1 ... 2 Display of C1436
PT1
C0640 Delay T 20.00 0.01 {0.01 s} 50.00 Time constant of the PT1-1 component
C1641 CFG: 1-1IN 1000 FIXED0
@
Selection list 1 SP value for IN1-1
[C1642] DIS: 1-1IN Display of C1641
R/L/Q
[C0885] CFG: R 51 DIGIN 1
@
Selection list 2 Digital input (CW rotation) of R/L/Q
[C0886] CFG: L 52 DIGIN 2
@
Selection list 2 Digital input (CCW rotation) of R/L/Q
C0889
1
2
DIS: C0885
DIS: C0886
Display of
C0885
C0886
REFC
C0011 Nmax 3000 500 {1 rpm} 16000 Maximum speed
Reference value for the absolute and relative setpoint
selection for the acceleration and deceleration times.
l
Parameter setting via interface:
Large changes in one step should only be made
when the controller is inhibited.
C0474
1
FCODE PH
0 -2147483648 {1} 2147483648 Freely assignable code for phase signals
1 rev. = 65536 inc
[C0920] CFG: ON 1000 FIXED0
@
Selection list 2 Activation input homing
[C0921] CFG: MARK 1000 FIXED0
@
Selection list 2 Digital reference switch
[C0922] CFG: PHI-IN 1000 FIXED0INC
@
Selection list 3 Phase input
[C0923] CFG: N-IN 1000 FIXED0%
@
Selection list 1 Speed input
[C0924] CFG: POS-LOAD 1000 FIXED0
@
Selection list 2 Control set position”
[C0925] CFG: ACTPOS-I 1000 FIXED0INC
@
Selection list 3 Position set position”