Configuration
7-317
SHB9300CRV EN 2.0
Code ImportantPossible settingsLCDCode Important
SelectionLenze
LCD
C0926
1
2
3
4
DIS: C0925
DIS: C0922
DIS: ACTPOS
DIS: TARGET
-2147483647 {1 inc} 2147483647 Display of
1. C0925
2. C0922
3. Display of the actual position
4. Display of the target position
C0927
1
2
3
DIS: C0920
DIS: C0921
DIS: LOAD
Display of
1. C0920
2. C0921
3. C0924
C0928 DIS: C0922 -2147483647 {1 inc} 2147483647 Phase signal (contouring error) of REF
l
1 rev. = 65536 inc
C0929 DIS: C0923 -199.99 {0.01 %} 199.99 Analog input signal
[C0930] Gearbox mot 1 1 {1} 65535 Gearbox factor (numerator)
[C0931] Gearbox enc 1 1 {1} 65535 Gearbox factor (denominator)
C0932 REF mode 0
0 Mode 0
1 Mode 1
6 Mode 6
7 Mode 7
8 Mode 8
9 Mode 9
20 Mode 20
21 Mode 21
Homing mode
C0933 REF tra ns 0
0 Rising trans
1 Falling trans
Reference signal transition
rising transition
falling transition
C0934 REF offset 0 -2140000000 {1 inc} 2140000000 Home position offset
C0935 REF speed 2.0000 0.0001 {0.0001 % N
max
} 100.0000 Homing speed
C0936 REF Ti 1.00 0.01 {0.01 s} 990.00 T
i
time homing
l
Tir and Tif are identical
C0937 CFG: DFIN 1000 FIXEDPHI-0
C0938 DIS: C0937 Display of C0937
RFG
C0671 RFG1 Tir 0.000 0.000 {0.01 s} 999.900 Acceleration time T
ir
of ramp function gene-
rator RFG1
C0672 RFG1 Tif 0.000 0.000 {0.01 s} 999.900 Deceleration time T
if
of RFG1
[C0673] CFG: IN 1000 FIXED 0 %
@
Selection list 1 Configuration analog input of RFG1
[C0674] CFG: SET 1000 FIXED0 %
@
Selection list 1 Configuration set input of RFG1
[C0675] CFG: LOAD 1000 FIXED 0
@
Selection list 2 Digital input of RFG1
C0676
1
2
DIS: C0673
DIS: C0674
-199.99 {0.01 %} 199.99 Display of
C0673
C0674
C0677 DIS: C0675 Display of C0675
RFGPH
C1400
1
2
3
CFG: RESET
CFG: RFG-0
CFG: T/DIST
1000 FIXED 0
@
Selection list 2 1. HIGH = sets RFGPH1-OUT = 0 (jump)
LOW = RFGPH1-OUT is set to the value at
RFGPH1-IN according to the selected function
Input has priority over RFGPH1-RFG-0
2. HIGH = proceeds according to the selected function
RFGPH1-OUT = 0
LOW = RFGPH1-OUT is set to the value at
RFGPH1-IN according to the selected function
3. Function changeover HIGH = path-based path
change
LOW = time-based path change
C1401 DIS: C1400/1 ... 3 Display of C1400
C1402
1
2
CFG: IN
CFG: DIST
1000 FIXED0 INC
@
Selection list 3 1. Position setpoint (65536 inc = 1 rev.)
2. Path difference by which the path is to be changed
at the input -IN (65536 inc = 1 rev.)
C1403 DIS: C1402/1 ... 2 Display of C1402
C1404 CFG: DFIN 1000 FIXEDPHI-0
@
Selection list 4 Digital frequency input
C1405 DIS: C1404 Display of C1404
C1408 Speed 300.0 -16000.0000 {0.0001 rpm} 16000.0000