Commissioning
5-11
SHB9300CRV EN 2.0
5.7.2 Cam profile import
6
9
7
5
8
2
10
4
3
1
Kurv_imp
11
Fig. 5-6 Dialog Cam profile import
Commissioning procedure
1
A name for a file to be imported can be entered direcly or...
2
..selected from a disk by using the button Open”.
3
After the selection of a file, a number of information about the data read in is indicated in the middle left screen area.
Indicated are the value pairs (pointsI and
4
the minimum values in X and Ydirection
5
as well as the maximum values in X and Ydirection.
6
Select the target profile for the imported data in the upper screen area.
7
The data are transferred to the controller.
8
After data transmission, they must be accepted from the active data range of the controller (button Accept data). For this,
connect the signal CDATA-LOAD (C1322/7) temporarily to FIXED1; reset to FIXED0 afterwards.
9
The converted data can be stored on a data carrier by pressing the button Speichern”
10
The button Display profile leads to the corresponding program dialog.
(See on-line help)
11
The button Check profile starts the calculation of the profile characteristic and checks whether the required conditions are met.
Show/Hide Bookmarks

Table of Contents

Related product manuals