Important notes
10
Function library
10.2
L
10.2-1
EDS82EV903-1.0-11/2002
10.2 Important notes
The function library provides detailed information on how to adapt the controller
to your application.
In order to control the controller or output status messages, internal digital and
analog signal can be freely linked with sources and targets.
Maloperation can be avoided by observing the following:
l Select the source from the targets point of view:
Ask yourself Where does the signal come from?
That makes it easy to find the correct entry for a code.
l A source can have several targets:
It is thus possible that double assignments occur when targets are
assigned to sources.
Ensure that only the targets wanted are assigned to a source.
For instance, the assignment of E1 remains the same even if the
frequency input E1 is activated (Lenze setting: JOG1 activation!). The
previous assignment must be deleted with C0410/1 = 255 to ensure
trouble-free operation.
l A target can have one source only.
The code table serves as a reference book including all functions with brief
explanations.
( 10.20-1 ff.)
The signal flow diagrams show the integration of the codes into the internal signal
processing.
( 16.1-1 ff.)
Correct signal linkage
Overview of code table and
signal flow diagram