Operation with increased rated power
Rated data for mains voltage 400 V
4
Technical data
4.4
4.4.2
L
4.4-6
EDS82EV903-1.0-11/2002
Maximum motor power
P
r
[kW] 22 30 37
Three-phase
C asynchronous motor
(4 pole)
P
r
[hp] 30 40 50
8200 vector type With mains filter E82EV153K4B3xx E82EV223K4B3xx -
Without mains filter E82EV153K4B2xx
1)
E82EV223K4B2xx
1)
E82EV303K4B2xx
1) 4)
Mains voltage U
mains
[V] 3/PE AC 320 V - 0 % ... 440 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
DC
[V] DC 450 V - 0 % ... 625 V + 0 %
Data for op eration with 3/PE AC 400 V or DC 565 V
Rated mains current
without mains choke/mains f ilter I
mains
[A] - - -
with mains chokde/mains filter I
mains
[A] 39.0 50.0 60.0
Output power U, V, W S
N4
[kVA] 29.8 39.5 46.4
Output power +U
G
,-U
G
2)
P
DC
[kW] 10.2 4.0 0
Rated output current at 1kHzsin
chopper frequency
2kHzsin I
r
[A] 32 47 59
4kHzsin
1kHz
2kHz I
r
[A] 43 56 66
4kHz
Max. permissible 1kHzsin
output current for 60 s
2kHzsin I
max
[A] 48 70.5 89
at chopper frequency
3)
4kHzsin
1kHz
2kHz I
max
[A] 48 70.5 89
4kHz
Output voltage
without mains choke/mains f ilter U
M
[V] 3~ 0 ... V
mains
/ 0 ... 650 H z
with mains chokde/mains filter U
M
[V] 3~ 0 ... approx. 94 % V
mains
/ 0 ... 650 H z
Power loss (operation with I
r8
) P
v
[W] 430 640 810
Required mains choke type] ELN3-0075H045 ELN3-0055H055 ELN3-0055H055
Dimensions
with mains f ilter H x W x D [mm] 350 x 250 x 340
without mains filter H x W x D [ mm] 350 x 250 x 250
Weight
with mains f ilter m[kg] 34
without mains filter m[kg] 15
1)
Operation only with mains choke or mains f ilter
2)
For operation with power-adapted motors additional power to be t aken from the DC bus
3)
Currents for periodic load change : 1 min overcurrent with I
max
and 2 min basic load with 75 % I
r
4)
Maximum permissible ambient operating temperature +35 °C