5 EtherCAT
Configuration
20 Lenze · Inverter i550 - Cabinet · Ethernet Manual · 0.1 EN · 12/2015
Explicit device identification:
This mechanism is necessary if the device is part of a 'Hot Connect'-group, to prevent cable swapping or the de-
vice is used within a modular machine application of Lenze.
To identify the device explicitly one of the following mechanisms can be used within the i-series devices:
A master can use the 'Configured station alias' address of the slave. For the i-series this is possible by setting
the relevant register within the configuration EPM with direct access from the master.
Setting an identification value with the rotary switch. With a value >0 this value is valid and used to identify
the device.
If the switch is set to 0 the identification value can be set with the parameter 0x2361:4 (P510:4). A value >0
explicitly identifies the device.
The active device identification value is displayed in the parameter 0x2362:4 (P511:4). The identification value (/
Station alias) has to be unique in the network. Using one of the identification mechanisms the master references
the devices with these values.
See chapter 2.2 Rotary Selector (EtherNet/IP, EtherCAT only) on page 7 for details about rotary switch.
P508:0
0x2360:0
Activate network (*)
i550
R/W
0: No action/no error
1: Restart with actual values
10: In progress
11: Action cancelled
12: Fault
Controls network activities
P
0x1000:0
Device type (*)
i550
R
-- ... [Actual value] ... --
Device type
P
0x1008:0
Manufacturer device name (*)
i510
i550
R
-- ... [Actual value] ... --
Manufacturer device name
P
0x1009:0
Manufacturer HW version (*)
i550
R
-- ... [Actual value] ... --
Manufacturer Hardware revision
P
0x100A:0
Manufacturer software version (*)
i510
i550
R
-- ... [Actual value] ... --
Manufacturer Software revision
P
0x1018:1
Vendor ID (*)
i510
i550
R
-- ... [Actual value] ... --
Object identification: Revision: Vendor ID
Lenze is 0x0000003B = 59
P
0x1018:2
Product code (*)
i510
i550
R
-- ... [Actual value] ... --
Object identification: Product Code
P
0x1018:3
Revision (*)
i510
i550
R
-- ... [Actual value] ... --
Object identification: Revision
P
0x1018:4
Serial number (*)
i510
i550
R
-- ... [Actual value] ... --
Object identification: Serial number of the device. Note that it does not
represent the Lenze serial number (0x2000:2)
P509:0
0x2363:0
Switch setting (*)
i550
R
-- ... [Actual value] ... --
Displays the current rotary switch setting. The active identification is
displayed in 0x2362:4.
P510:4
0x2361:4
Device identifier (*)
i550
R/W
-- ... [0] ... --
Set the explicit device identification value of the device with an object.
(valid if rotary switches are set to 0)