5 EtherCAT
Configuration
20 Lenze · Inverter i550 - Cabinet · Ethernet Manual · 0.1 EN · 12/2015
Explicit device identification:
This mechanism is necessary if the device is part of a 'Hot Connect'-group, to prevent cable swapping or the de-
vice is used within a modular machine application of Lenze.
To identify the device explicitly one of the following mechanisms can be used within the i-series devices:
A master can use the 'Configured station alias' address of the slave. For the i-series this is possible by setting
the relevant register within the configuration EPM with direct access from the master.
Setting an identification value with the rotary switch. With a value >0 this value is valid and used to identify
the device.
If the switch is set to 0 the identification value can be set with the parameter 0x2361:4 (P510:4). A value >0
explicitly identifies the device.
The active device identification value is displayed in the parameter 0x2362:4 (P511:4). The identification value (/
Station alias) has to be unique in the network. Using one of the identification mechanisms the master references
the devices with these values.
See chapter 2.2 Rotary Selector (EtherNet/IP, EtherCAT only) on page 7 for details about rotary switch.
0: No action/no error
1: Restart with actual values
10: In progress
11: Action cancelled
12: Fault
Controls network activities
-- ... [Actual value] ... --
Manufacturer device name (*)
-- ... [Actual value] ... --
Manufacturer HW version (*)
-- ... [Actual value] ... --
Manufacturer Hardware revision
Manufacturer software version (*)
-- ... [Actual value] ... --
Manufacturer Software revision
-- ... [Actual value] ... --
Object identification: Revision: Vendor ID
Lenze is 0x0000003B = 59
-- ... [Actual value] ... --
Object identification: Product Code
-- ... [Actual value] ... --
Object identification: Revision
-- ... [Actual value] ... --
Object identification: Serial number of the device. Note that it does not
represent the Lenze serial number (0x2000:2)
-- ... [Actual value] ... --
Displays the current rotary switch setting. The active identification is
displayed in 0x2362:4.
Set the explicit device identification value of the device with an object.
(valid if rotary switches are set to 0)