5 EtherCAT
Diagnostics
Lenze · Inverter i550 - Cabinet · Ethernet Manual · 0.1 EN · 12/2015 21
5.3 Diagnostics
Active settings can be checked in the Parameters listed below:
P511:4
0x2362:4
Active device identifier (*)
i550
R
-- ... [Actual value] ... --
Displays the active explicit device identifier value
P511:6
0x2362:6
Active station address (*)
i550
R
-- ... [Actual value] ... --
Display the active EtherCAT station address of the device
P511:7
0x2362:7
Active Tx length (*)
i550
R
-- ... [Actual value] ... --
Display the length of transmitted cyclic data in bytes
P511:8
0x2362:8
Active Rx length (*)
i550
R
-- ... [Actual value] ... --
Display the length of received cyclic data in bytes
P516:0
0x2368:0
Network status (*)
i550
R
1: Initialisation
2: Pre-Operational
3: Bootstrap
4: SafeOperational
8: Operational
Display the communication status of the device
P517:0
0x2369:0
Bus error (*)
i550
R
-- ... [Actual value] ... --
Indicates a bus error
5.4 Errors and Error Reaction
P515:1
0x2859:1
Watchdog elapsed (*)
i550
R/W
2:Trouble
(Reference see P310:1)
Fault reaction for fieldbus : Watchdog expired
P515:3
0x2859:3
Invalid confg by Master (*)
i550
R/W
2:Trouble
(Reference see P310:1)
Fault reaction for fieldbus : Invalid Configuration by Master
P515:4
0x2859:4
Stack initialization error (*)
i550
R/W
2:Trouble
(Reference see P310:1)
Fault reaction for fieldbus : Fieldbus stack initialization error
P515:5
0x2859:5
Invalid process data (*)
i550
R/W
2:Trouble
(Reference see P310:1)
Fault reaction for fieldbus: Invalid process data