EasyManua.ls Logo

Lenze i550

Lenze i550
61 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Drive Profile
AC Drive Profile
Lenze · Inverter i550 - Cabinet · Ethernet Manual · 0.1 EN · 12/2015 55
Drive State: Lenze CIA402 state machine to Ethernet/IP Drive State conversion table:
CiA402 Plus State
AC Drive Profile Drive State
INIT (0, 1)
0 - Vendor Specific
NOT_READY_TO_SWITCH_ON (2)
1 = Startup
SWITCH_ON_DISABLED (3)
2 = Not_Ready
READY_TO_SWITCH_ON (4)
SWITCHED_ON (5)
3 = Ready
OPERATION_ENABLED (6)
4 = Enabled
DISABLE_OPERATION (7)
SHUT_DOWN (8)
QUICK_STOP (9)
5 = Stopping
FAULT_REACTION_ACTIVE (10)
6 = Fault_Stop
FAULT (11)
7 = Faulted
7.3.3 Speed setpoint / Actual Speed
Several speed command formats are also available:
P592:3
0x400B:3
Network frequency setpoint
i510
i550
R/W
0.0 ... [0.0] ... 599.0 Hz
Legacy network frequency setpoint
Scaling: 0.1 Hz unsigned (direction information comes via control word)
P592:4
0x400B:4
Network setpoint speed
i510
i550
R/W
0 ... [0] ... 50000 rpm
Legacy network speed setpoint
Scaling: RPM unsigned (direction information comes via control word)
P592:5
0x400B:5
Network setp. frequency
i510
i550
R/W
0.00 ... [0.00] ... 599.00 Hz
Legacy network frequency setpoint
Scaling: 0.01 Hz unsigned (direction information comes via control word)
P592:6
0x400B:6
Network speed setpoint
i510
i550
R/W
-599.0 ... [0.0] ... 599.0 Hz
Legacy network frequency setpoint
Scaling: 0.1 Hz signed
Several actual speed formats are also available:
P593:3
0x400C:3
Actual frequency Hz
i510
i550
R
-- ... [Actual value] ... -- Hz
Legacy actual frequency
Scaling 0.1Hz, unsigned
P593:4
0x400C:4
Actual motor speed RPM
i510
i550
R
-- ... [Actual value] ... -- rpm
Legacy actual speed
Scaling RPM, unsigned
P593:6
0x400C:6
Actual frequency
i510
i550
R
-- ... [Actual value] ... -- Hz
Legacy actual frequency
Scaling 0.01Hz, unsigned

Table of Contents

Other manuals for Lenze i550

Related product manuals