4 PROFINET
PROFINET Connection to Engineering Tools
16 Lenze · Inverter i550 - Cabinet · Ethernet Manual · 0.1 EN · 12/2015
9. Start/Stop the drive
- With the default IO-setting DI1 need to be asserted (Run/Stop)
- Set “Network frequency setpoint 0.01Hz”, (Example 1234 = 12.34 Hz)
- Set Bit 3 of “Lenze control word (NetWordIN1)” to start the drive
Per default the watchdog timeout response for the communication is set to trouble (0x2859:1, P515:1).
4.7 PROFINET Connection to Engineering Tools
1. Power the device externally either by mains or external 24V supply and connect the inverter to the PC using
the USB diagnostic adapter.
2. Set address and station name:
The station name, the IP address, subnet mask, and gateway address can either be assigned by the PLC-
controller via PROFINET or set manually in the Easy Starter.
If the settings are done with Easy Starter set the following parameters:
a. Communication parameters:
Name Parameter Example:
IP Address 0x2381:1 (P510:1) 192.168.178.2
Subnet 0x2381:2 (P510:2) 255.255.255.0
Gateway 0x2381:3 (P510:3) (Normally not needed)
Station name 0x2381:4 (P510:4) i550_MainDrive
b. Save the parameter with 0x2022:3 (P700:3) and power cycle the drive that the configuration takes
effect.
3. Connect the PC to the i500 PROFINET with an Ethernet cable.
4. Set the IP address of the network adapter in your PC to the same range than the inverter IP address.
Example:
IP Address 192.168.178.1
Subnet 255.255.255.0
Select the connection “Ethernet” in the Easy Starter
Set the correct IP address of the device and add it. Now the objects of the inverter are accessible in Easy
Starter.