Inverter i550-C45/400-3 i550-C55/400-3 i550-C75/400-3
Cable installaon in compliance with EN 60204-1
Laying system C F
operaon
Fuse
Characteriscs -
Max. rated current A - - -
Circuit breaker
Characteriscs -
Max. rated current A - - -
operaon with mains choke
Fuse
Characteriscs gR
Max. rated current A 125 160 160
Circuit breaker
Characteriscs B -
Max. rated current A 125 - -
Earth-leakage circuit breaker
3-phase mains connecon ≥ 300 mA, type B
Mains connecon
Connecon X100
Connecon type Screw terminal
Min. cable cross-secon mm² 10 25
Max. cable cross-secon mm² 50 95
Stripping length mm 19 22
Tightening torque Nm 4 10
Required tool Allen key 4.0 Allen key 6.0
Motor connecon
Connecon X105
Connecon type Screw terminal
Min. cable cross-secon mm² 10 25
Max. cable cross-secon mm² 50 95
Stripping length mm 19 22
Tightening torque Nm 4 10
Required tool Allen key 4.0 Allen key 6.0
Technical data
3-phase mains connecon 480 V
Fusing and t