Mechanical installation
Standard devices in a power range of 30 ... 45 kW
Assembly without filter in ”standard” technique
5
139
EDS84ASC552 EN 10.0
Assembly without filter in ”standard” technique
For mounting, use four screws M8 x >16 mm. The mounting location and material must
ensure a durable mechanical connection.
ƒ Screw and washer assemblies or hexagon socket screws with washers are
recommended..
How to proceed:
1. Prepare the fixing holes on the mounting surface.
2. Screw the controller directly to the mounting surface.
StateLine, HighLine
8400GG108e
Fig. 5-41 Device dimensions
h b t h
1
h
2
t
1
g
1
g
2
g
3
[kW] [mm]
E84AVxxE3034xXx30
450 250 250 520 636 237 8.5 16 18
E84AVxxE3734xXx 37
E84AVxxE4534xXx 45
E84AVxxE3034xBx 30
450 250 270 520 636 257 8.5 16 18
E84AVxxE3734xBx 37
E84AVxxE4534xBx 45