Sample Printouts of Standard Reports
Figure 4-81, Figure 4-82 and Figure 4-83 are examples of a Federal
Standard Ft3, ISO 14644-1 and a EU GMP 2009 reports.
Note:
If a recipe is
loaded, the name of the
recipe will be printed on
the report.
Figure 4-81 Sample Federal Standard 209E (ft
3
) report
*************
Fed Standard 209E_Ft^3
**HANDHELD 3016**
Serial #: 130602021
Targeted Class: 10000
Room Area: 10.00ft^2
Room Status: Operational
Air Flow: Unidirect
Min Loc: 2
Min Samples/Room: 5
Recipe: TEST
-----
06/20/2013, 09:09:08
-----
Particle Size: 0.3
Cumulative, p/ft^3
Vol Req: 0.100 ft^3
Concen Limit: 30800
-----
Loc Samples AvgConcen
LOC001 5 6114.0
LOC002 5 4572.0
-----
Mean: 5343.0
StdDev: 1090.4
StdError: 771.0
95% UCL: 10208.0
Min Vol: 0.100 ft^3
-----
Particle Size: 0.5
Cumulative, p/ft^3
Vol Req: 0.100 ft^3
Concen Limit: 10000
-----
Loc Samples AvgConcen