Service Training
Section 2.6
Page 84
Batterie OK
*Linde Test Module**
** Version 2.94 **
** Device Ready **
* No Data received *
- Depress the ENTER button to store the new value (NW).
- The newly programmed value (PW) appears in the third line of the display.
M N E W
N W
- After the battery test there will appear
M N E W
N W
P W
* Data end *
- Depress the DATEN NEU (new data) button.
- Enter the menu number.
- The selected menu number (MN) will appear and the current value (EW).
- The programmed value can be modified with the + and - buttons. The new value (NW) will appear
in the second line of the display.
2.6.11.1.1 PROGRAMMING OF MENU FUNCTIONS 11 TO 24
- Connect the diagnostic unit to the truck data connector. The data connector is located behind the
left switch cover at the instrument panel.
- Turn on the key switch.
- Depress the EIN (on) button. If the internal batteries are OK, the following message will appear on
the display