5 Maintenance
Engine
ation can be started at any time within this
period.
¾ Press the starting switch (7) in the switch
panel downwards and hold for approx.
3 seconds until the integrated yellow switch
illumination (operating display) lights up.
The particle filter alarm (3) goes out in the
display unit.
The operation indicator sta
ys lit up until the
end of the regeneration proc
ess (approx. 23
minutes).
If the particle alarm was activated before
regeneration is restarted, it remains active.
In this case, a full regeneration must be
performed immediately.
CAUTION
The engine cannot be started during regeneration.
If the truck has to be moved from a safety area or
regeneration has to be interrupted for safety rea-
sons, the stop/reset switch (8) must be unlocked
and pressed. The regeneration process will imme-
diately be terminated, and the truck can be started.
If the regeneration process has been interrupted,
the particle filter will not have been regenerated!
Regeneration should only be interrupted in an
emergency as this may lead to system damage.
¾ In the event of an emergency, unlock and
press the stop/reset switch (8) in the switch
panel.
In the event of an error occurring during
regeneration, the error light (2) or the particle
filter alarm (3) lights up and an error code
appears in the text field (5) of the display unit
(1).
Start regeneration again. If the malfunction
still persists, switch off the truck. Please
contact your authorised dealer.
NOTE
To switch off the buzzer, press the reset button
(6). If the buzzer continues to sound, please
contact your authorised dealer. Whilst driving,
the glow plug of the regeneration system
is cleaned after 1.75 hours by intermediate
heating.
148 Operating Instructions – 394 807 10 01 EN – 07/2011