Maintenance 5
Self-help
appears in the text field (10) of the display
unit, a fault occurred during regeneration.
Restart regeneration procedure.
Only if a changing particle filter is fitted:
If the orange indicator light (14) lights up
in the switch panel in the top right and a
buzzer sounds, the filter must be changed
or regenerated within the next 30 minutes.
If the indicator light (4) fla
shes, there is an
error in the electrical cont
roller. Depending
on the setting and error, it m
ay only be
possible to drive the truck a
t low speed
or not at all. Each error is in
dicated by a
numerical code or symbols in
the text field
(10). Contact your authori
sed dealer.
If the indicator light (13) flashes, there is
an error in the engine or the engine control
unit. Switch off the engine. Contact your
authorised dealer.
If the air filter vacuum indicator (11) lights
up on the display unit, maintenance must
be performed on the air filter.