LINXON Warning and error messages | 7
LX218-Operating-Manual-en1-04-(1908) 73 / 90
No. of the
warning
message
Displayed message Description and possible remedy for the
cause
W130 Preamplifier temperature is
too low. (<2°C)
• The ambient temperature is too low.
• The temperature sensor in the
preamplifier is defective.
• Preamplifier cable is defective.
After confirmation of this warning message,
a warning triangle will remain in the "Ready"
menu, indicating the presence of this fault.
Only if this fault is eliminated will this
warning triangle disappear.
W131 Preamplifier temperature is
too high. (>60°C)
• The ambient temperature is too high.
• The air filter is soiled.
• Heat build-up due to unfavorable position
• Temperature sensor in the preamplifier
defective.
After confirmation of this warning message,
a warning triangle will remain in the "Ready"
menu, indicating the presence of this fault.
Only if this fault is eliminated will this
warning triangle disappear.
W132 Temperature at the
electronic unit is too low (<
2 °C).
• Ambient temperature too low
• Temperature sensor is defective
After confirmation of this warning message,
a warning triangle will remain in the "Ready"
menu, indicating the presence of this fault.
Only if this fault is eliminated will this
warning triangle disappear.
W133 Temperature at electronic
unit is too high! (>55°C)
• The ambient temperature is too high.
• Unfavorable position of the leak detector.
(Heat build-up)
• Fan failed.
• Air filter too heavily contaminated.
• Temperature sensor defective.
After confirmation of this warning message,
a warning triangle will remain in the "Ready"
menu, indicating the presence of this fault.