What is what?
MultiPress S Operating manual 3.0 Rev 3.6.2009 19
2.3 Hand pump
WARNING
Risk of injury!
Under high pressure standing leaky fittings can solve uncontrol-
lably. Spouting hydraulic oil can cause eye and skin injuries.
Switch off the MultiPress S and ensure that the manometer on the
hand pump shows 0 bar (0 psi) before tightening/loosening the
screw connetion of the hydraulic hose.
WARNING
Risk of crushing.
During pumping the pumping lever is lowered down to the
carrying handle. This may result in limbs being crushed between
the lever and the carrying handle.
During pumping, do not hold the hand pump on the carrying
handle.
Fig. 4: Hand pump
1 Pump lever
2 Carrying handle
3 Manometer
4 Threaded connection for hydraulic hose
5 Handwheel for pressure relief valve
6 Screw cap for oil tank
123
4
5
6