Operation
MultiPress S Operating manual 3.0 Rev 3.6.2009 43
The following values can be changed in the press profiles:
Tab. 3: Menu Profiles > Change
6.5 Starting the program
A program is started using the press profile shown in the profile box (see
"Selecting and editing press profiles" on page 41). Please note that the
press profile selected last is automatically preselected, after switching on
the MultiPress S.
Note: Prior to pressing, the multilayer materials and consumables must
be stored at room temperature for 24 hours, cleaned and heat-treated.
Observe the information given in Chapter 6.6.1‚ "Preparing the
materials", on page 50.
MultiPress S with hand
pump:
Before starting a press program, observe the information on the
operation of the hand pump (see chapter 6.8‚ "Operating the hand
pump", on page 54) and familiarize yourself with its use.
Menu item Function/Explanation Unit Preset min. max.
prehe.temp Preheating temperature
°C 250 30 250
prepre.temp Prepressing temperature
°C 150 30 250
presstemp Main pressing
temperature
°C 180 30 250
width Width of the multilayer
mm 305 100 305
height Length of the multilayer
mm 229 100 229
pp-force Prepressing force
N/cm² 80 30 286
mp-force Main pressing force
N/cm² 150 30 286
preptime Prepressing time
min 10 1 60
presstime Main pressing time
min 60 1 120
Tip: Use the Table 6, "Individual configuration of the press profiles", on
page 72, to log the changed values.