MultiPress S Operating manual 3.0 Rev 3.6.2009 45
Note: You can stop the preheating stage at any time by pressing the
ESC key, for example in order to select a different press profile or restart
the preheating stage at a later time.
After the preheating temperature defined in the press profile (must temp.)
has been reached, the Start menu is displayed, and the entry Pressing
is preselected. A short acoustic signal, repeated at an interval of three
seconds, indicates that the material should be inserted.
6.5.2 Starting the pressing stages
The prepressing stage must not be started until the preheating
temperature has been reached. Once the preheating stage is complete, a
repeated acoustic signal will sound, and in the Start menu the entry
Pressing is preselected.
Make sure that the desired press profile is displayed in the profile
box.
Position the press mold containing the multilayer in the press.
(see
chapter 6.6‚ "Loading the press system", on page 50)
Fig. 17: Display in the
Setup menu
s t a r t LPKF S e t
P r e s s
ESC f a n o n ENT
2 0 ° C 2 0 ° C