Operation
48 MultiPress S Operating manual 3.0 Rev: 3.6.2009
Make sure that the pressure on the manometer always corresponds
to the target pressure during the entire cooling stage. If necessary,
correct it by additional pumping.
The cooling stage is finished automatically upon reaching the preset
fan temperature. A repeated acoustic signal will sound, and the
message "finished" will appear.
Observe the information regarding the removal of the multilayer (see
chapter 6.6.4‚ "Removing the multilayer", on page 53).
Canceling/Quitting the program
A program in progress should only be stopped in case of emergency. If a
press process is interrupted, no matter during which stage, this may
result in air inclusions and material distortion in the multilayer. Thus, a
correct pressing can no longer be guaranteed.
To end a program prematurely, proceed as follows:
Press the ESC key.
This immediately stops the program. The main menu is displayed,
and "preheat" is selected in the selection box.
Observe the information regarding the removal of the multilayer (see
chapter 6.6.4‚ "Removing the multilayer", on page 53).