5 -40
5-11. Every 1000hr or 1-year check
Primary
element
Evacuator valve
Safety filter
element
(1) Replacing Air cleaner element
(Dry type)
If the air-cleaner service indicator in the
instrument panel is turned on, make sure to
check and/or replace the filter element
regardless of recommended service intervals in
this maintenance chart.
Remove the cover and pull the primary element
straight out, ensuring the safety filter element
remains in place.
Clean the inside of the air cleaner housing using
a clean damp cloth, being careful not to damage
the safety element.
Check if there is any damage inside the filter element by using a light. If finding a tiny crack or small
holes in the filter element or the gasket is damaged, change it with a new one.
Insert the filter element deeply into the filter housing.
Remove the dust of the evacuator valve and clean the inside of the cover.
Assemble the cover with the evacuator valve facing downwards.
▶ Do not start the engine or close the hood if the filter element is not assembled..
Notice