Page #44 background image
Chapter 5. Table of Functions
42
Code
Comm.
Address
Name LCD Display Setting Range
Initial
Value
Property*
V/F
SL
Ref.
for press
76
21
0h134C
Compensation
frequency limit of
regeneration
evasion for press
CompFreq
Limit
0.00- 10.00Hz 1.00 X/A O O
77
21
0h134D
Regeneration
evasion for press
P gain
RegenAvd
Pgain
0.0- 100.0% 50.0 O/A O O
78
21
0h134E
Regeneration
evasion for press I
gain
RegenAvd
Igain
20-30000(ms) 500 O/A O O
80
0h1350
Fire mode
selection
Fire Mode Sel
0
None
0:None X/A O X
1
Fire Mode
2
Fire Mode
Test
81
22
0h1351
Fire mode
frequency
Fire Mode
Freq
0.00~60.00(Hz] 60.00 X/A O X
82
22
0h1352
Fire mode
direction
Fire Mode Dir
0
Forward
0:
Forward
X/A O X
1 Reverse
83
22
Fire Mode Count
Fire Mode Cnt
Can not be
modified
21
Displayed when Ad.74 is set to 1 (Yes).
22
Displayed when Ad.80 is set to 1 (Yes).

Other manuals for LSIS S100 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS S100 Series and is the answer not in the manual?

LSIS S100 Series Specifications

General IconGeneral
BrandLSIS
ModelS100 Series
CategoryController
LanguageEnglish

Related product manuals