This operation manual is intended for users with basic knowledge of electricity and electric
devices.
* LSLV-S100 is the official name for S100.

Table of Contents

Other manuals for LSIS LSLV-S100

Questions and Answers

  • T
    Tamara MillerSep 23, 2025
    What does Option Trip- 1 mean on an LSIS Inverter?
    • S
      Sarah PrinceSep 23, 2025
      The 'Option Trip- 1' message on your LSIS Inverter indicates that a communication error has been detected between the inverter and the communication board.
  • A
    Alex MendozaAug 23, 2025
    What does Over Voltage mean on an LSIS Inverter?
    • A
      andrea33Aug 23, 2025
      The 'Over Voltage' message on your LSIS Inverter means that the internal DC circuit voltage exceeds the specified value.
  • M
    Melanie GregoryAug 25, 2025
    What does Over Current1 mean on an LSIS Inverter?
    • C
      Christopher ReevesAug 26, 2025
      The 'Over Current1' message on your LSIS Inverter indicates that the inverter output current exceeds 200% of the rated current.
  • C
    chernandezAug 27, 2025
    What does Ground Trip* mean on an LSIS Inverter?
    • B
      bmartinezAug 27, 2025
      The 'Ground Trip*' message on your LSIS Inverter indicates that a ground fault trip has occurred on the output side of the inverter, causing the current to exceed the specified value.
  • V
    Victoria CoxAug 27, 2025
    Why does my LSIS Inverter display Inverter OLT?
    • R
      Rachael PatelAug 27, 2025
      The 'Inverter OLT' message on your LSIS Inverter means the inverter has been protected from overload and resultant overheating, based on inverse time-limit thermal characteristics.
  • M
    Mr. Adam RobinsonSep 16, 2025
    What does Safety A(B) Err mean on an LSIS Inverter?
    • G
      Gary LopezSep 16, 2025
      The 'Safety A(B) Err' message on your LSIS Inverter indicates that at least one of the two safety input signals is off.
  • J
    Jill VegaSep 13, 2025
    What does Pre-PID Fail mean on an LSIS Inverter?
    • K
      keith27Sep 13, 2025
      The 'Pre-PID Fail' message on your LSIS Inverter indicates that pre-PID is operating with functions set at AP.34–AP.36.
  • N
    Nicole TurnerSep 15, 2025
    What does Ext-Brake mean on an LSIS Inverter?
    • M
      mkrauseSep 15, 2025
      The 'Ext-Brake' message on your LSIS Inverter operates when the external brake signal is provided by the multi-function terminal.
  • K
    Kathleen SmithSep 5, 2025
    What does Out Phase Open mean on an LSIS Inverter?
    • C
      Christopher MooreSep 5, 2025
      The 'Out Phase Open' message on your LSIS Inverter indicates that a 3-phase inverter output has one or more phases in an open circuit condition. This operates when bit 1 of parameter Pr.05 is set to 1.
  • V
    Vicki HowellSep 3, 2025
    What does Lost Command mean on an LSIS Inverter?
    • T
      Tracy LaneSep 3, 2025
      The 'Lost Command' message on your LSIS Inverter indicates that a frequency or operation command error has been detected during inverter operation by controllers other than the keypad.

Summary

Preparing the Installation

Product Identification

Details on identifying the S100 inverter product name, including model and specifications on the rating plate.

Installation Considerations

Details ideal operating and installation conditions, including ambient temperature, humidity, and altitude.

Selecting and Preparing a Site for Installation

Provides guidelines for choosing an installation location and preparing the site, emphasizing ventilation.

Cable Selection

Information on selecting appropriate power and signal cables for safe and reliable operation.

Installing the Inverter

Mounting the Inverter

Procedures for mounting the inverter on a wall or inside a panel, ensuring sufficient clearance.

Cable Wiring

Instructions for opening covers and completing power and control terminal block connections, with safety precautions.

Ground Connection

Instructions for removing covers and installing the ground connection for the inverter and motor.

Power Terminal Wiring

Shows the terminal layout and descriptions for making power terminal wiring connections.

Control Terminal Wiring

Illustrates the detailed layout of control wiring terminals and control board switches.

Post-Installation Checklist

A checklist to verify safe and correct installation of the inverter, covering location, wiring, and connections.

Test Run

Instructions for testing the inverter after installation, including verifying motor rotation and acceleration/deceleration.

Learning to Perform Basic Operations

About the Keypad

Describes the keypad layout, display components, and operation keys for basic inverter functions.

Operation Keys

Details the names and functions of the keypad's operation keys for controlling the inverter.

Control Menu

Lists the function groups under Parameter mode for 0.4-22kW models, explaining their purpose.

Learning to Use the Keypad

Explains keypad navigation for groups, codes, and setting parameter values.

Setting Parameter Values

Instructions on how to set or modify parameter values for different codes, covering frequency, voltage, and speed.

Learning Basic Features

Learning Protection Features

Motor Protection

Protects the motor from overheating damage using electronic thermal prevention (ETH).

Overload Early Warning and Trip

Warns or trips when the motor reaches an overload state based on rated current.

Stall Prevention and Flux Braking

Prevents motor stall caused by overloads, adjusting frequency automatically.

Inverter and Sequence Protection

Protects the inverter against malfunction due to external signals or internal circuit issues.

Open-phase Protection

Prevents overcurrent induced at inverter inputs due to an open-phase in the input power supply.

Inverter Overload Protection

Protects the inverter from damage when input current exceeds the rated current.

Speed Command Loss

Selects inverter operation for situations when the speed command is lost.

Under Load Fault Trip and Warning

Addresses fault trips and warnings related to underload conditions.

Fault;Warning List

Lists types of faults and warnings that can occur during S100 inverter usage.

Table of Functions

Protection Function group (PAR→Pr)

Lists protection function group parameters.

Troubleshooting

Trips and Warnings

Explains how to read warning messages and understand fault conditions like Level, Latch, and Fatal.

Fault Trips

Lists protection functions for output current and input voltage, detailing keypad display, type, and description.

Warning Messages

Displays warning messages for motor overload, underload, lost command, and fan warning.

Troubleshooting Fault Trips

Provides a table of possible causes and remedies for fault trips and warnings.

Troubleshooting Other Faults

Addresses various other faults not classified as trips or warnings, suggesting causes and remedies.

Technical Specification

Input and Output Specification

Details input and output specifications for various inverter models, including applied motor, rated output, and rated input.

LSIS LSLV-S100 Specifications

General IconGeneral
BrandLSIS
ModelLSLV-S100
CategoryController
LanguageEnglish