5.4 3-Wire Operation
The 3-wire operation latches the signal input (the signal stays on after the button is
released), and is used when operating the inverter with a push button.
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
Operation
drv
Command
source
Cmd Source*
1
Fx/Rx - 1
-
-
In
65-71
Px terminal
configuration
Px Define
(Px: P1-P7)
14
3-Wire
0~54
-
* Displayed under DRV-06 in an LCD keypad.
To enable the 3-wire operation, the following circuit sequence is necessary. The minimum
input time (t) for 3-wire operation is 1ms, and the operation stops when both forward and
reverse operation commands are entered at the same time.
[Terminal connections for 3-wire operation]
[3-wire operation]