136
Learning Basic Features
Manual Torque Boost Setting Details
Code
Description
dr.16 Fwd Boost
Set torque boost for forward operation.
dr.17 Rev Boost
Set torque boost for reverse operation.
Excessive torque boost will result in over-excitation and motor overheating .
Auto Torque Boost-1
Auto torque boost enables the inverter to automatically calculate the amount of output
voltage required for torque boost based on the entered motor parameters. Because auto
torque boost requires motor-related parameters such as stator resistance, inductance, and
no-load current, auto tuning (bA.20) has to be performed before auto torque boost can be
configured [Refer to 5.9 Auto Tuning on page 183]. Similarly to manual torque boost,
configure auto torque boost while running a load that requires high starting torque, such as
lift-type loads.
Group
Code
Name
LCD Display
Parameter
Setting
Setting Range
Unit
Dr
15
torque boost mode
Torque
Boost
1
Auto1
02
-
bA
20
auto tuning
Auto Tuning
3
Rs+Lsigma
06
-