Learning Advanced Features
Setting range of the user group code. Entering 0 cancels
the settings.
Set a code number () to use to register the parameter in
the user group. Select code number and press [PROG/ENT]
key.
Changing the value in will also change the value in . If
no code is registered, ‘Empty Code’ will be displayed.
Entering 0 cancels the settings.
The registered parameters are listed in the user group in U&M
mode. You can register one parameter multiple times if
necessary. For example, a parameter can be registered as
code 2, code 11, and more in the user group.
Follow the procedures below to delete parameters in the user group.
Set CNF- 42 to 3(UserGrp SelKey). A icon will be
displayed at the top of the LCD display.
In the USR group in U&M mode, move the cursor to the code
that is to be deleted.
Move to YES on the deletion confirmation screen, and press
the [PROG/ENT] key.
Set to 1(Yes) to delete all registered parameters in the user group.
5.28 Easy Start On
Run Easy Start On to easily setup the basic motor parameters required to operate a motor
in a batch. Set CNF-61(Easy Start On) to 1(Yes) to activate the feature, initialize all
parameters by setting CNF-40 (Parameter Init) to 1 (All Grp), and restart the inverter to
activate Easy Start On. This function is only available on the LCD loader.
Parameter easy start
settings