Learning Advanced Features
249
cumulated electric energy consumption. Power consumption is displayed as shown below:
Less than 1,000 kW: Units are in kW, displayed in 999.9 kW format.
199 MW: Units are in MW, displayed in 99.99 MWh format.
100999 MW: Units are in MW, displayed in 999.9 MWh format.
More than 1,000 MW: Units are in MW, displayed in 9,999 MWh format and can be displayed
up to 65,535 MW. (Values exceeding 65,535MW will reset the value to 0, and units will return
to kW. It will be displayed in 999.9 kW format).
5.38 Operation Time Monitor
Monitors inverter and fan operation time. This function is only available on the LCD loader.
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
CNF
70
Inverter operation
accumulated time
On-time
0/00/00 00:00
-
min
71
Inverter operation
accumulated time
Run-time
0/00/00 00:00
-
min
72
Inverter operation
accumulated time
initialization
Time Reset
0
No
01
-
74
Cooling fan operation
accumulated time
Fan time
0/00/00 00:00
-
min
75
Cooling fan operation
accumulated time
initialization
Fan Time
Reset
0
No
01
-
Operation Time Monitor Setting Details
Code
Description
CNF-70 On-time
Displays accumulated power supply time. Information is displayed in
[YY/MM/DD Hr: Min (0/00/00 00: 00)] format.
CNF-71 Run-time
Displays accumulated time of voltage output by operation command
input. Information is displayed in [YY/MM/DD Hr: Min (0/00/00 00: 00)]
format.
CNF-72 Time Reset
Setting 1(Yes) will delete power supply accumulated time (On-time) and
operation accumulated time (Run-time) and is displayed as 0/00/00 00:00
format.
CNF-74 Fan time
Displays accumulated time of inverter cooling fan operation. Information
will be displayed in [YY/MM/DD Hr: Min (0/00/00 00: 00)] format.
CNF-75 Fan Time
Reset
Setting 1(Yes) will delete cooling fan operation accumulated time(on-time)
and operation accumulated time (Run-time) and will display it in 0/00/00
00:00 format.

Table of Contents

Other manuals for LSIS LSLV-S100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LSIS LSLV-S100 and is the answer not in the manual?

LSIS LSLV-S100 Specifications

General IconGeneral
BrandLSIS
ModelLSLV-S100
CategoryController
LanguageEnglish

Related product manuals