Table of Functions
353
8.12 User Sequence group (US)
This group appears when AP.02 is set to 1 (Yes) or CM.95 is set to 2 (P2P Master). The
parameter cannot be changed while the user sequence is running.
SL: Sensorless vector control function (dr.09) , I IM Sensorless, P PM Sensorless
*O/X: Write-enabled during operation, 7/L/A: keypad/LCD keypad/common
Code
Comm.
Address
Name
LCD Display
Setting
Range
Initial
Value
Property*
V/
F
SL
Ref.
00
-
Jump code
Jump Code
1-99
31
O/A
O
I/P
p.71
01
0h1D01
User sequence
operation
command
User Seq Con
0
Stop
0:Stop
X/A
O
I/P
p.149
1
Run
2
Digital In
Run
02
0h1D02
User sequence
operation loop
time
US Loop Time
0
0.01s
1:0.02
s
X/A
O
I/P
p.149
1
0.02s
2
0.05s
3
0.1s
4
0.5s
5
1s
11
0h1D0B
Output address
link1
Link UserOut1
0-0xFFFF
0
X/A
O
I/P
p.149
12
0h1D0C
Output address
link2
Link UserOut2
0-0xFFFF
0
X/A
O
I/P
p.149
13
0h1D0D
Output address
link3
Link UserOut3
0-0xFFFF
0
X/A
O
I/P
p.149
14
0h1D0E
Output address
link4
Link UserOut4
0-0xFFFF
0
X/A
O
I/P
p.149
15
0h1D0F
Output address
link5
Link UserOut5
0-0xFFFF
0
X/A
O
I/P
p.149
16
0h1D10
Output address
link6
Link UserOut6
0-0xFFFF
0
X/A
O
I/P
p.149
17
0h1D11
Output address
link7
Link UserOut7
0-0xFFFF
0
X/A
O
I/P
p.149
18
0h1D12
Output address
link8
Link UserOut8
0-0xFFFF
0
X/A
O
I/P
p.149
19
0h1D13
Output address
link9
Link UserOut9
0-0xFFFF
0
X/A
O
I/P
p.149
20
0h1D14
Output address
link10
Link
UserOut10
0-0xFFFF
0
X/A
O
I/P
p.149
21
0h1D15
Output address
link11
Link
UserOut11
0-0xFFFF
0
X/A
O
I/P
p.149
22
0h1D16
Output address
link12
Link
UserOut12
0-0xFFFF
0
X/A
O
I/P
p.149
23
0h1D17
Output address
link13
Link
UserOut13
0-0xFFFF
0
X/A
O
I/P
p.149

Table of Contents