118
Learning Basic Features
Terminal Block as a Command Input Device (Fwd/Rev Run
Commands)
Multi-function terminals can be selected as a command input device. This is configured by
setting the drv (command source) code in the Operation group to 1(Fx/Rx). Select 2
terminals for the forward and reverse operations, and then set the relevant codes (2 of the 5
multi-function terminal codes, In.6571 for P1P7) to 1(Fx) and 2(Rx) respectively. This
application enables both terminals to be turned on or off at the same time, constituting a
stop command that will cause the inverter to stop operation.
Group
Code
Name
LCD Display
Parameter
Setting
Setting
Range
Unit
Operation
drv
Command
source
Cmd Source*
1
Fx/Rx-1
05
-
In
6571
Px terminal
configuration
Px Define
(Px: P1 P7)
1
Fx
054
-
2
Rx
* Displayed under DRV-06 on the LCD keypad.
Fwd/Rev Command by Multi-function Terminal Setting Details
Code
Description
Operation group
drv Cmd Source
Set to 1(Fx/Rx-1).
In.6571 Px
Define
Assign a terminal for forward (Fx) operation.
Assign a terminal for reverse (Rx) operation.