232
Learning Advanced Features
5.32 Multi-Function Output On/Off Control
Set reference values (on/off level) for analog input and control output relay or multi-function
output terminal on/off status accordingly.
Group
Code
Name
LCD Display
Parameter
Setting
Setting Range
Unit
Ad
66
Output terminal on/off
control mode
On/Off Ctrl Src
1
V1
-
-
67
Output terminal on
level
On-C Level
90.00
Output terminal
off level
100.00%
%
68
Output terminal off
level
Off-C Level
10.00
0.00Output
terminal on level
%
OU
31
Multi-function relay1
item
Relay 1
34
On/Off
-
-
33
Multi-function output1
item
Q1 Define
Multi-function Output On/Off Control Setting Details
Code
Description
Ad.66 On/Off Ctrl Src
Select analog input On/Off control.
Ad.67 On-C Level ,
Ad.68 Off-C Level
Set On/Off level at the output terminal.