EasyManua.ls Logo

LSIS LSLV-S100 - 6 Learning Protection Features; Motor Protection; Electronic Thermal Motor Overheating Prevention (ETH)

LSIS LSLV-S100
469 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
250
Learning Protection Features
6 Learning Protection Features
Protection features provided by the S100 series inverter are categorized into two types:
protection from overheating damage to the motor, and protection against the inverter
malfunction.
6.1 Motor Protection
Electronic Thermal Motor Overheating Prevention (ETH)
ETH is a protective function that uses the output current of the inverter without a separate
temperature sensor, to predict a rise in motor temperature to protect the motor based on its
heat characteristics.
Group
Code
Name
LCD Display
Parameter
Setting
Setting range
Unit
Pr
40
Electronic thermal
prevention fault trip
selection
ETH Trip Sel
0
None
0-2
-
41
Motor cooling fan
type
Motor Cooling
0
Self-cool
-
-
42
Electronic thermal
one minute rating
ETH 1min
150
120-200
%
43
Electronic thermal
prevention
continuous rating
ETH Cont
120
50-150
%
Electronic Thermal (ETH) Prevention Function Setting Details
Code
Description
Pr.40 ETH Trip Sel
ETH can be selected to provide motor thermal protection. The LCD
screen displays E-Thermal.
Setting
Function
0
None
The ETH function is not activated.
1
Free-Run
The inverter output is blocked. The motor coasts to
a halt (free-run).
2
Dec
The inverter decelerates the motor to a stop.
Pr.41 Motor Cooling
Select the drive mode of the cooling fan, attached to the motor.

Table of Contents