122
Learning Basic Features
Analog commands via terminal input: the inverter will continue to run without interruption
based on the command at the terminal block. If a reverse operation (Rx) signal is ON at the
terminal block at startup, the inverter will operate in the reverse direction even if it was
running in the forward direction in local operation mode before the reset.
Digital source commands: all command sources except terminal block command sources
(which are analog sources) are digital command sources that include the keypad, LCD
keypad, and communication sources. The inverter stops operation when switching to
remote operation mode, and then starts operation when the next command is given.
Use local/remote operation mode switching only when it is necessary. Improper mode switching
may result in interruption of the inverters operation.
4.7 Forward or Reverse Run Prevention
The rotation direction of motors can be configured to prevent motors to only run in one
direction. Pressing the [REV] key on the LCD keypad when direction prevention is
configured, will cause the motor to decelerate to 0Hz and stop. The inverter will remain on.
Group
Code
Name
LCD Display
Parameter Setting
Setting Range
Unit
Ad
09
Run prevention options
Run Prevent
0
None
02
-
1
Forward Prev
2
Reverse Prev
Forward/Reverse Run Prevention Setting Details
Code
Description
Ad.09 Run
Prevent
Choose a direction to prevent.
Setting
Description
0
None
Do not set run prevention.
1
Forward Prev
Set forward run prevention.
2
Reverse Prev
Set reverse run prevention.