Torque reference setting details
Select an input method to use as the torque reference.
Sets the torque reference with the keypad.
Sets the torque reference using the voltage or
current input terminal of the terminal block.
Sets the torque reference with the communication
terminal of the terminal block.
Input the torque reference using the inverter's
FieldBus option.
Enters torque reference by linking common area
with the user sequence output.
Input the torque reference using the pulse input
on the inverter's terminal block.
The torque reference can be set up to 180% of the maximum rated motor
torque.
Sets the maximum torque. You can check the set maximum torque in
Monitor (MON) mode.
Select a parameter from the Config(CNF) mode and then select(19 Torque
Ref).
Speed limit details
Select a method for setting the speed limit value.
Sets the speed limit value with the keypad.
Sets the speed limit value using the same
method as the frequency command. You can
check the setting in Monitor (MON) mode.
Sets the positive-direction speed limit value.
Sets the negative-direction speed limit value.
Sets the decrease rate of the torque reference when the motor speed