209
Group
Code
Name
LCD Display
Parameter Setting
Unit
23
Monitor mode display 3
Monitor Line-3
3
Output Voltage
*Available on LCD keypad only.
Torque reference setting details
Code
Description
dr-08
Select an input method to use as the torque reference.
Parameter Setting
Description
0
Keypad-1
Sets the torque reference with the keypad.
1
Keypad-2
2,4,5
V1,V2,I2
Sets the torque reference using the voltage or
current input terminal of the terminal block.
6
Int 485
Sets the torque reference with the communication
terminal of the terminal block.
8
FieldBus
Input the torque reference using the inverter's
FieldBus option.
9
UserSeqLink
Enters torque reference by linking common area
with the user sequence output.
12
Pulse
Input the torque reference using the pulse input
on the inverter's terminal block.
Cn-02
The torque reference can be set up to 180% of the maximum rated motor
torque.
In-02
Sets the maximum torque. You can check the set maximum torque in
Monitor (MON) mode.
CNF-2123
Select a parameter from the Config(CNF) mode and then select(19 Torque
Ref).
Speed limit details
Code
Description
Cn-62
Select a method for setting the speed limit value.
Parameter Setting
Description
0
Keypad-1
Sets the speed limit value with the keypad.
1
Keypad-2
2,4,5
V1,V2,I2
Sets the speed limit value using the same
method as the frequency command. You can
check the setting in Monitor (MON) mode.
6
Int 485
7
FieldBus
8
UserSeqLink
Cn-63
Sets the positive-direction speed limit value.
Cn-64
Sets the negative-direction speed limit value.
Cn-65
Sets the decrease rate of the torque reference when the motor speed