208
Learning Advanced Features
Note
To operate in torque control mode, basic operation conditions must be set. For more
information, refer to page 193.
The torque control cannot be used in a low speed regeneration area or low load conditions.
If you change the rotation direction while operating, an over current trip or low speed reverse
direction error will be generated.
Torque reference setting option
The torque reference can be set using the same method as the target frequency setting. If
Torque Control Mode is selected, the target frequency is not used.
Group
Code
Name
LCD Display
Parameter Setting
Unit
dr
02
Torque command
Cmd Torque
-180-180
%
08
Torque reference setting
Trq Ref Src
0
Keypad-1
-
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
8
FieldBus
9
UserSeqLink
12
Pulse
Cn
62
Speed limit setting
Speed LmtSrc
0
Keypad-1
-
1
Keypad-2
2
V1
4
V2
5
I2
6
Int 485
7
FieldBus
8
UserSeqLink
63
Positive-direction speed limit
FWD Speed Lmt
0-Maximum frequency
Hz
64
Negative-direction speed
limit
REV Speed Lmt
0- Maximum frequency
Hz
65
Speed limit operation gain
Speed Lmt Gain
100-5000
%
In
02
Torque at maximum analog
input
Torque at 100%
-12.00-12.00
mA
CNF*
21
Monitor mode display 1
Monitor Line-1
1
Speed
22
Monitor mode display 2
Monitor Line-2
2
Output Current