Table of Functions
317
Code
Comm.
Address
Name
LCD Display
Setting Range
Initial
Value
Property*
V/F
SL
Ref.
upper limit3
Maximum
frequency(Hz)
41
20
0h1329
Brake
release
current
BR Rls Curr
0.0-180.0(%)
50.0
O/A
O
I/P
p.231
42
20
0h132A
Brake
release delay
time
BR Rls Dly
0.00-10.00(s)
1.00
X/A
O
I/P
p.231
44
20
0h132C
Brake
release
Forward
frequency
BR Rls Fwd
Fr
0.00-Maximum
frequency(Hz)
1.00
X/A
O
I/P
p.231
45
20
0h132D
Brake
release
Reverse
frequency
BR Rls Rev
Fr
0.00-Maximum
frequency(Hz)
1.00
X/A
O
I/P
p.231
46
20
0h132E
Brake
engage delay
time
BR Eng Dly
0.00-10.00(s)
1.00
X/A
O
I/P
p.231
47
20
0h132F
Brake
engage
frequency
BR Eng Fr
0.00-Maximum
frequency(Hz)
2.00
X/A
O
I/P
p.231
50
0h1332
Energy
saving
operation
E-Save
Mode
0
None
0:None
X /A
O
X
p.207
1
Manual
2
Auto
51
21
0h1333
Energy
saving level
Energy
Save
0-30(%)
0
O/A
O
X
p.207
60
0h133C
Acc/Dec time
transition
frequency
Xcel
Change Fr
0.00-Maximum
frequency(Hz)
0.00
X/A
O
I/P
p.129
61
0h133D
Rotation
count speed
gain
Load Spd
Gain
0.1~6000.0[%]
100.0
O/A
O
I/P
-
62
0h133E
Rotation
count speed
scale
Load Spd
Scale
0
x 1
0: x 1
O/A
O
I/P
-
1
x 0.1
2
x 0.01
3
x 0.001
4
x 0.0001
63
0h133F
Rotation
count speed
unit
Load Spd
Unit
0
Rpm
0: rpm
O/A
O
I/P
-
1
mpm
64
0h1340
Cooling fan
FAN Control
0
During Run
0:Durin
O/A
O
I/P
p.220
20
Displayed if either OU.31~33 is set to 35 (BR Control).
21
Displayed if Ad.50 is not set to 0 (None).