Chapter 5. Table of Functions
45
Cod
e
Addres
s
Name LCD Display Setting Range
Initial
Value
Property*
V/F
SL
Ref.
regeneration
torque limit
62
26
0h143E
Speed limit
Setting
Speed Lmt Src
0:
Keypa
d-1
X/A X O
63
26
0h143F
speed limit
FWD Speed Lmt
frequency (Hz)
60.00 O/A X O
64
26
0h1440
direction speed
limit
REV Speed Lmt
0.00~ Maximum
frequency (Hz)
60.00 O/A X O
65
26
0h1441
operation gain
Speed Lmt Gain 100~5000[%] 500 O/A X O
70
0h
1446
Speed search
mode selection
SS Mode
27
Flying
Start-1
X/A O O
1 Flying Start-2
71 0h1447
Speed search
operation
selection
Speed Search
0000
28
X/A O O
00
01
search
on acceleration
00
10
initialization
after fault trip
01
00
after
instantaneous
power
interruption
00
with power on
72
29
0h1448
reference current
SS Sup-Current 80-200(%) 150 O/A O O
73
30
0h1449
Speed search
proportional gain
SS P-Gain 0-9999
Start-1
: 100
O/A O O
Start-2
: 600
31
27
Will not be displayed if dr.09 is set to 4 (IM Sensorless).
28
The initial value 0000 will be displayed on the keypad as .
29
Displayed when any of the Cn.71 code bits are set to 1 and Cn70 is set to 0 (Flying Start-1).
30
Displayed when any of the Cn.71 code bits are set to 1.
31
The initial value is 1200 when the motor-rated capacity is less than 7.5 kW