NGT-9000
Pilot’s Guide 2-39
Operation
Activate
Maintenance Mode?
No
Yes
Maintenance
Screen Calibration >
Reboot >
Reboot
Main App >
< Back
Maint No-WiFi >
Maint With-WiFi >
Ground Test >
Figure 2-26: Maintenance Screens
Touch and Release Target
In the Calibration screen touch and release each target shown.
(Four calibration targets and two verification targets). Each must
be completed within 15 seconds or the Calibration Time out
message is shown. The unit returns to the main screen.
If normal operation is desired cycle power to the unit or tap the
Reboot text on the main screen followed by tapping the Main App
> text to perform a warm startup.
When in normal operation check that the touch screen accuracy
has improved. If the accuracy has not improved, try the calibration
procedure again. If the issue continues contact L-3 Avionics
Systems Field Service for help in resolving the issue prior to
removing the unit for repair.
5.
6.
7.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lynx NGT-9000 Series and is the answer not in the manual?

Lynx NGT-9000 Series Specifications

General IconGeneral
TypeAvionics Display
DisplayLCD
Operating Temperature-20°C to +55°C
InterfaceARINC 429, RS-232
ADS-BADS-B In/Out

Related product manuals