57-606 ECLIPSE Model 706 Guided Wave Radar Transmitter
3.5 Agency Approvals
T
hese units are in compliance with the EMC-directive 2014/30/EU,
t
he PED-directive 2014/68/EU and the ATEX directive 2014/34/EU.
Explosion Proof (with intrinsically Safe Probe)
US/Canada:
Class I, Div 1, Group B, C and D, T4
Class I, Zone 1 AEx d/ia [ia IIC Ga] IIB + H2 T4 Gb/Ga
C
lass I, Zone 1 Ex d/ia [ia IIC Ga] IIB + H2 T4 Gb/Ga
Ta = -40ºC to +70ºC
Type 4X, IP67
Flame Proof
ATEX – FM14ATEX0041X:
II 2/1 G Ex d/ia [ia IIC Ga] IIB + H2 T6 to T1 Gb/Ga
Ta = -40ºC to +70ºC
IP67
IEC- IECEx FMG 14.0018X:
Ex d/ia [ia IIC Ga] IIB + H2 T6 to T1 Gb/Ga
Ta = -40ºC to +70ºC
IP66/67
Non- Incendive
US/Canada:
Class I, II, III, Division 2, Group A, B, C, D, E, F, G, T4
Class I, Zone 2 AEx ia/nA [ia Ga] IIC T4 Ga/Gc
C
lass I, Zone 2 Ex ia/nA [ia Ga] IIC T4 Ga/Gc
Ta = -40ºC to +70ºC
Type 4X, IP67
ATEX FM14ATEX0042X:
II 1/3 G Ex ia/nA [ia Ga] IIC T4 Ga/Gc
Ta = -15ºC to +70ºC
IP67
IEC IECEx FMG 14.00018X:
Ex ia/nA [ia Ga] IIC T4 Ga/Gc
Ta = -15ºC to + 70ºC
IP66/67
Intrinsically Safe
US/Canada:
Class I, II, III, Div 1, Group A, B, C, D, E, F, G, T4,
Class I, Zone 0 AEx ia IIC T4 Ga
Class I, Zone 0 Ex ia IIC T4 Ga
Ta =-40ºC to + 70ºC
Type 4X, IP67
ATEX – FM14ATEX0041X:
II 1 G Ex ia IIC T4 Ga
Ta = -40ºC to +70ºC
IP67
IEC IECEx FMG 14.0018X:
Ex ia IIC T4 Ga
Ta = -40ºC to +70ºC
IP66/67
Dust Ignition Proof
US/Canada:
Class II, III, Division 1, Group E, F and G, T4
Ta = -40ºC to +70ºC
Type 4X, IP67
ATEX – FM14ATEX0041X:
II 1/2 D Ex ia/tb [ia Da] IIIC T85ºC to T450ºC Da/Db
Ta = -15ºC to +70ºC
IP67
IEC IECEx FMG 14.0018X:
Ex ia tb [ia Da] IIIC T75ºC to T435ºC Db
Ex ia IIIC T75ºC to T435ºC Da
Ta = -15ºC to +70ºC
IP66/67
The following approval standards are applicable:
FM3600:2011, FM3610:2010, FM3611:2004, FM3615:2006, FM3616:2011, FM3810:2005, ANSI/ISA60079-0:2013,
ANSI/ISA 60079-1:2009, ANSI/ISA 60079-11:2013, ANSI/ISA 60079-15:2012, ANSI/ISA 60079-26:2011, NEMA 250:2003,
ANSI/IEC 60529:2004, C22.2 No. 0.4:2009, C22.2 No. 0.5:2008, C22.2 No. 30:2007, C22.2 No. 94:2001, C22.2 No. 157:2012,
C22.2 No. 213:2012, C22.2 No. 1010.1:2009, CAN/CSA 60079-0:2011, CAN/CSA 60079-1:2011, CAN/CSA 60079-11:2011,
CAN/CSA 60079-15:2012, C22.2 No. 60529:2005, EN60079-0:2012, EN60079-1:2007, EN60079-11:2012, EN60079-15:2010,
EN60079-26:2007, EN60079-31:2009, EN60529+A1:1991-2000, IEC60079-0:2011, IEC60079-1:2007, IEC60079-11:2011,
IEC60079-15:2010, IEC60079-26:2006, IEC60079-31:2008