82
57-606 ECLIPSE Model 706 Guided Wave Radar Transmitter
1 | TECHNOLOGY
2 | MEASUREMENT SYSTEM
3 | CONFIGURATION/STYLE (RIGID)
7
7 ECLIPSE GWR Probes - Model 706
A English
C Metric
D
Enlarged Coaxial, High Temp/High Pressure: Overfill w/Glass Seal (+850 °F/+450 °C)Only available with 10th digit N or D
P
Enlarged Coaxial, High Pressure: Overfill w/Glass Seal (+400 °F/+200 °C) Only available with 10th digit N or D
T
Enlarged Coaxial, Overfill Standard O-Ring Seal (+400 °F/+200 °C) NOT available with 10th digit N or D
Torque Tube Mating Flanges ¡
T T 600# Fisher (249B/259B) in carbon steel
T U 600# Fisher (249C) in stainless steel
U T 600# Masoneilan flange in carbon steel
U U 600# Masoneilan flange in stainless steel
4 5 | PROCESS CONNECTION SIZE/TYPE (consult factory for other process connections)
Threaded
ANSI Flanges
4 3
2" 150# ANSI RF ¿
4 4
2" 300# ANSI RF ¿
4 5
2" 600# ANSI RF ¿
4 K
2" 600# ANSI RTJ ¿
5 3 3" 150# ANSI RF
5 4 3" 300# ANSI RF
5 5
3" 600# ANSI RF
56
3" 900# ANSI RF
57
3" 1500# ANSI RF
58
3" 2500# ANSI RF
5K
3" 600# ANSI RTJ
5L
3" 900# ANSI RTJ
4 1
2" NPT Thread ¿
5M 3" 1500# ANSI RTJ
5N 3" 2500# ANSI RTJ
6 3 4" 150# ANSI RF
6 4 4" 300# ANSI RF
6 5 4" 600# ANSI RF
6 6 4" 900# ANSI RF
6 7 4" 1500# ANSI RF
6 8 4" 2500# ANSI RF
6K 4" 600# ANSI RTJ
6L 4" 900# ANSI RTJ
6M 4" 1500# ANSI RTJ
6N 4" 2500# ANSI RTJ
EN Flanges
D A
DN 50, PN 16 EN 1092-1 TYPE A ¿
D B
DN 50, PN 25/40 EN 1092-1 TYPE A ¿
D D
DN 50, PN 63 EN 1092-1 TYPE B2 ¿
D E
DN 50, PN 100 EN 1092-1 TYPE B2 ¿
E A DN 80, PN 16 EN 1092-1 TYPE A
E B DN 80, PN 25/40 EN 1092-1 TYPE A
E D DN 80, PN 63 EN 1092-1 TYPE B2
E E DN 80, PN 100 EN 1092-1 TYPE B2
E F DN 80, PN 160 EN 1092-1 TYPE B2
E G
DN 80, PN 250 EN 1092-1 TYPE B2
E H DN 80, PN 320 EN 1092-1 TYPE B2
E J DN 80, PN 400 EN 1092-1 TYPE B2
F A DN 100, PN 16 EN 1092-1 TYPE A
F B DN 100, PN 25/40 EN 1092-1 TYPE A
F D DN 100, PN 63 EN 1092-1 TYPE B2
F E DN 100, PN 100 EN 1092-1 TYPE B2
F F DN 100, PN 160 EN 1092-1 TYPE B2
F G
DN 100, PN 250 EN 1092-1 TYPE B2
F H
DN 100, PN 320 EN 1092-1 TYPE B2
F J
DN 100, PN 400 EN 1092-1 TYPE B2
4 2
2" BSP (G1) Thread ¿
¿ Confirm mounting conditions/nozzle diameter to ensure sufficient clearance.
¡ Always check dimensions if ANSI/EN flanges are not used.
12 3 456 7 8 910 11 12 13 14 15
3
.7.2 Enlarged Coaxial Probe