Removing the Slew Sensor
1. Disconnect transducer connectors (2) from slew sensor
(1).
2. Remove capscrews (3), washers (4), left pinion
protection shield (5), and slew sensor (1).
3. Remove capscrews (6), washers (7), and plate (8) as
necessary.
Installing the Slew Sensor
1. Install plate (8) on superstructure with washers (7) and
capscrews (6).
2. Install slew sensor assembly (1) and left pinion
protection shield (5) with washers (4) and capscrews (3).
3. Connect transducer connectors to slew sensor
assembly.
4. If install new transducers, you must re-calibrate the
sensors. For more information, see Calibrating ODM
Sensors, page 3-20.