9-13
GRT9165 SERVICE MANUAL MAINTENANCE AND LUBRICATION
9
Published 10-01-2020 Control # 699-00
GROVE
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Approximate
Capacity
Service Interval
Service
Application
Drive Train (Continued)
5b
Transmission and
Torque Converter
Filter
Figure 9-3
PERFORM after first
50 hours of service,
and
REPLACE
transmission and
torque converter
filter
See NOTE 11.
REPEAT after
another 50 hours for
a total of 100 hours of
service
REPLACE
transmission and
torque converter
filter
THEN every
1000 hours, or
6 months, thereafter
whichever interval
comes first
REPLACE
transmission and
torque converter
filter
5c
Transmission
Fluid FILL and
DIPSTICK
Figure 9-3 J
44.5 L
(11.75 gal)
As necessary, in
DRAIN and FILL
routines
FILL transmission
sump to FULL on
DIPSTICK
See NOTE 13.
NOTE 13: The Transmission Fluid FILL and DIPSTICK is in a remote location for ease of servicing the transmission.

Table of Contents

Other manuals for Manitowoc Grove GRT9165

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc Grove GRT9165 and is the answer not in the manual?

Manitowoc Grove GRT9165 Specifications

General IconGeneral
BrandManitowoc
ModelGrove GRT9165
CategoryConstruction Equipment
LanguageEnglish

Related product manuals