ECODRIVE03 SMT-02VRS Description of Diagnostic Letters B..., C..., D... and A... 4-39
DOK-ECODR3-SMT-02VRS**-WA01-EN-P
A400 Automatic drive check and adjustment
Diagnosis A400 is a group diagnosis for various system states. It is used
in drive checks and adjustments. A through diagnosis is automatically run
when the drive enable is switched on and off.
Drive checks and adjustments include systems states that are run
through independent on parametrization.
sequence of holding brake delay time (see P-0-0526, Brake control
delay)
structure of air gap field (is asynchronous motor)
automatic determination of commutation offset (if synchronous motor
with incremental measuring system)
Depending on parametrization, the following system status is checked.
Automatic brake monitor (see P-0-0538, Motor function
parameter 1)
A401 Drive deceleration to standstill
The drive
is brought to standstill as defined in parameter P-0-0119, Best
possible deceleration or
carries out "velocity command value equals zero" after a travel range
error has occurred.
(see also functional description “General Instructions for Installation/
Definition of Terms, Introduction / Error".)
A800 Unknown operation mode
There is no diagnosis for the activated operation mode.