4-2 Description of Diagnostic Letters B..., C..., D... and A... ECODRIVE03 SMT-02VRS
DOK-ECODR3-SMT-02VRS**-WA01-EN-P
B000 Pulse wire/Resolver offset detection
Command P-0-0550, B000 Pulse wire/Resolver offset detection is
conducted.
B001 Motor does not have resolver feedback
If no motor with resolver feedback is connected, then command
P-0-0550, B000 Pulse wire/Resolver offset detection cannot be
conducted.
B002 Drive active at command start
If the drive is in control mode, then it is not possible to conduct command
P-0-0550, B000 Pulse wire/Resolver offset detection. Drive enable is
removed.
B003 Power supply is off
If the power supply is off, then it is not possible to conduct command
P-0-0550, B000 Pulse wire/Resolver offset detection.
B004 S pulse not found within travel range
S pulse was not found as pulse wire encoder is defective.
B005 Error writing to feedback EEPROM
An error occurred while writing via the IIC interface.
B006 Error in feedback processor, SDAI does not show 1
The feedback processor does not go into a ready state.
B008 Drive must be in operation mode (phase 4)
The drive is not in Phase 4 (bb).
B009 Drive does not control in secondary operation mode 1
The drive does not accept the internal drive enable.